To the Editor: Nosocomial Acinetobacter baumannii is commonly acquired through cross-transmission because of its propensity to survive in the hospital environment and persistently contaminate fomites. Since cell phones are used increasingly by health personnel worldwide, we sought to determine their role in nosocomial transmission of multidrug-resistant (MDR) A. baumannii.

The study was conducted in a tertiary-care hospital in Israel, where MDR Acinetobacter spp. is endemic. Cell phones are used by personnel both for private communication and instead of traditional pagers. During 2002, 124 personnel (71 physicians, 54 nurses) were screened randomly for Acinetobacter spp. in a point-prevalence study; samples from hands of 119 personnel and 124 cell phones were cultured simultaneously for 2 months. Swabs from the back and sides of the cell phones were cultured. Cultures of hand samples were done by using the broth-bag technique (1).

To assess cross-transmission between hands, cell phones, and patients, we studied 2 additional Acinetobacter spp. culture cohorts, nosocomial blood isolates from 2000 to 2002, and axilla and groin Acinetobacter spp. skin colonization in an intensive care unit (ICU) during 2002. Cohorts represent wards in which 73% of study personnel worked.

Isolates were identified by the ID20NE system (bioMérieux, Marcy l'Etoile, France) without differentiation between A. baumannii and species 3 and 13TU. Antimicrobial susceptibility was determined for aminoglycosides, penicillins, cephalosporins, carbapenems, fluoroquinolones, tetracyclines, polymyxin E, and ampicillin/sulbactam by using disk diffusion according to Clinical and Laboratory Standards Institute guidelines (2). MDR was defined as resistance ≥3 different classes.

Genotypic analysis of isolates from all cohorts was performed using pulsed-field gel electrophoresis. Chromosomal DNA was digested with ApaI and analyzed by using a CHEF-DRIII apparatus (Bio-Rad Laboratories, Hercules, CA, USA). Strain relatedness was interpreted according to consensus (3). Isolates showing an identical banding pattern were considered indistinguishable, and those showing differences of 3 bands were considered closely related.

Study personnel were assigned to medical (22%), surgical (44%), pediatric (23%), and ICU (11%) wards. The respective contamination rate with Acinetobacter spp. was 27%, 7.4%, 7.4%, and 0% for cell phones and 24%, 22%, 14%, and 41% for personnel hands. Of 30 hand and 15 cell phone cultures positive for Acinetobacter spp., 17% and 20%, respectively, were MDR.

Figure

Thumbnail of Pulsed-field gel electrophoresis of representative Acinetobacter strains. Twenty different clones (panel A) were recovered from cell phones (lanes no. 1, 3, 8–11) and hands of personnel (remaining lanes). Indistinguishable isolates were recovered from cellphones and hand cultures (lanes 11 and 12), and 2 hand cultures (lanes 18 and 19). Both pairs were obtained from different persons. Panel B shows a multidrug-resistant Acinetobacter spp. strain recovered from cell phones (lane 1),

Figure. . Pulsed-field gel electrophoresis of representative Acinetobacter strains. Twenty different clones (panel A) were recovered from cell phones (lanes no. 1, 3, 8–11) and hands of personnel (remaining lanes). Indistinguishable isolates...

Both hand and cell phone cultures of 3 personnel were positive (unrelated strains). Cell phone and hand isolates exhibited substantial clonal diversity. Acinetobacter spp. transmission (including MDR strains) was documented between hands, as well as between cell phones and hands, of different persons (Figure, panel A). One clone, recovered from cell phones and hands of ICU personnel, was also involved in skin colonization of ICU patients (Figure, panel B) but was unrelated to blood isolates.

We found that a significant percentage of cell phones and hands were contaminated with MDR Acinetobacter spp. and that cross-contamination between hands, cell phones, and patients occurred. Co-contamination of hands and cell phones was found in only 10% of cases and may be explained by small sample size and that personnel were sampled only once. Higher co-contamination would likely have been found with repeated sampling.

The ability of Acinetobacter spp. to contaminate cell phones is not unexpected; it has been isolated from numerous sources in hospital environments in outbreak and nonoutbreak settings. Contamination and nosocomial transmission of pathogens by other electronic devices also has been demonstrated; a contaminated personal computer has been implicated in transmission of methicillin-resistant Staphylococcus aureus to a nurse. Computer keyboards have been contaminated with staphylococci and Pseudomonas spp (4). Keyboards also have been implicated in nosocomial A. baumannii infection in burn units and ICUs (5) and have been contaminated with enterococci and Enterobacter spp with a genetically identical methicillin-resistant S. aureus strain (6).

Stationary phones may also harbor pathogens; stationary phones in a daycare facility were contaminated with rotavirus (7), and home phones were contaminated with enteroviral DNA (8). In the hospital, ≤47% of stationary phones were contaminated with pathogenic microbes (9). Hand-to-mouth transfer of microbes was documented after contaminated fomites were handled during casual activities, with the highest transfer efficiency noted with stationary phone receivers (10).

Thus, cell phones may have a notable role in the nosocomial transmission of MDR microbes to patients. Cell phones are particularly problematic compared to stationary devices and may facilitate intra- and inter-ward (and perhaps inter-hospital) transmission. Additionally, the potential for nosocomial transmission of MDR pathogens by other electronic devices, such as handheld computers or personal digital assistants, with bedside applications, should be recognized.

Since restriction or even prohibition of such devices may prove impractical, strategies for preventing nosocomial transmission in this context are needed, especially given the risk of continuing contamination through repeated hand–cell phone contact. Such strategies should target behavioral controls of personnel (enforcing infection control precautions), environmental disinfection, and ultimately, optimal disinfection methods that will prevent contamination without damaging these sensitive electronic devices.

This work has been presented in part at the 43rd Interscience Conference on Antimicrobial Agents and Chemotherapy, Chicago, IL, USA, September 2003.

Top

Abraham Borer*, Jacob Gilad*Comments to Author , Rozalia Smolyakov*, Seada Eskira*, Nechama Peled*, Nurith Porat*, Eytan Hyam*, Ronit Trefler*, Klaris Riesenberg*, and Francisc Schlaeffer*
Author affiliations: *Soroka University Medical Center and Ben-Gurion University of the Negev, Beer-Sheva, Israel

Top

References

  1. Larson  E, Lusk  E. Evaluating hand washing technique. J Adv Nurs. 1985;10:54752. DOIPubMedGoogle Scholar
  2. National Committee for Clinical Laboratory Standards (NCCLS). Performance standards for antimicrobial susceptibility testing, 11th informational supplement, NCCLS document M100-S11, Wayne (PA); 2001.
  3. Tenover  FC, Arbeit  RD, Goering  RV. Interpreting chromosomal DNA restriction patterns produced by pulsed-field gel electrophoresis: criteria for bacterial strain typing. J Clin Microbiol. 1995;33:22339.PubMedGoogle Scholar
  4. Isaacs  D, Daley  A, Dalton  D. Swabbing computers in search of nosocomial bacteria. Pediatr Infect Dis J. 1998;17:533. DOIPubMedGoogle Scholar
  5. Neely  AN, Maley  MP, Warden  GD. Computer keyboards as reservoirs for Acinetobacter baumannii in a burn hospital. Clin Infect Dis. 1999;29:135860. DOIPubMedGoogle Scholar
  6. Bures  S, Fishbain  JT, Uyehara  CFT. Computer keyboards and faucet handles as reservoirs of nosocomial pathogens in the intensive care unit. Am J Infect Control. 2000;28:46570. DOIPubMedGoogle Scholar
  7. Butz  AM, Fosarelli  P, Dick  J, Cusack  T, Yolken  R. Prevalence of rotavirus on high-risk fomites in day-care facilities. Pediatrics. 1993;92:2025.PubMedGoogle Scholar
  8. Bellamy  K, Laban  KL, Barreto  KE, Talbot  DC. Detection of viruses and body fluids which may contain viruses in the domestic environment. Epidemiol Infect. 1998;121:67380. DOIPubMedGoogle Scholar
  9. Singh  V, Aggarwal  V, Bansal  S, Garg  SP, Chowdhary  N. Telephone mouthpiece as a possible source of hospital infection. J Assoc Physicians India. 1998;46:3723.PubMedGoogle Scholar
  10. Rusin  P, Maxwell  S, Gerba  C. Comparative surface-to-hand and fingertip-to-mouth transfer efficiency of gram-positive bacteria, gram-negative bacteria, and phage. J Appl Microbiol. 2002;93:58592. DOIPubMedGoogle Scholar

Top

Figure

Top

Cite This Article

DOI: 10.3201/eid1107.050221

Related Links

Top

Table of Contents – Volume 11, Number 7—July 2005

EID Search Options
presentation_01 Advanced Article Search – Search articles by author and/or keyword.
presentation_01 Articles by Country Search – Search articles by the topic country.
presentation_01 Article Type Search – Search articles by article type and issue.

Top

Comments

Please use the form below to submit correspondence to the authors or contact them at the following address:

Jacob Gilad, Department of Internal Medicine E, Soroka University Medical Center, PO Box 151, Beer-Sheva, 84101, Israel; fax: 972-8-640-3366

Send To

10000 character(s) remaining.

Top

Page created: April 24, 2012
Page updated: April 24, 2012
Page reviewed: April 24, 2012
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.
file_external