Lisa Casanova*, Edie Alfano-Sobsey†, William A. Rutala*, David J. Weber*, and Mark Sobsey*Comments to Author 
Author affiliations: *University of North Carolina Chapel Hill, Chapel Hill, North Carolina, USA; †Wake County Human Services, Raleigh, North Carolina, USA;

Suggested citation for this article

Abstract

We evaluated a personal protective equipment removal protocol designed to minimize wearer contamination with pathogens. Following this protocol often resulted in virus transfer to hands and clothing. An altered protocol or other measures are needed to prevent healthcare worker contamination.

Caring for patients with communicable diseases places healthcare workers (HCWs) at risk. Infected HCWs may not only incur serious illness or death themselves but may spread infection to others. Methods to prevent HCW infections include vaccination (1), hand hygiene (2), and isolation of patients with communicable diseases (3).

A key aspect of patient isolation is proper use of personal protective equipment (PPE) to protect HCWs from pathogen exposure during patient care. PPE includes use of barriers (gowns, gloves, eye shields) and respiratory protection (masks, respirators) to protect mucous membranes, airways, skin, and clothing from contact with infectious agents (3). The importance of PPE was underscored in the recent outbreak of severe acute respiratory syndrome (SARS). HCWs accounted for ≈20% of cases (4); failure to properly use PPE was a risk factor for HCW infection (5).

Figure 1

Thumbnail of Figure 1 - Centers for Disease Control and Prevention protocol for removing healthcare worker PPE.

Figure 1. Centers for Disease Control and Prevention protocol for removing healthcare worker PPE.

This outbreak raised concern that HCWs could contaminate their skin or clothes with pathogens during PPE removal, resulting in accidental self-inoculation and virus spread to patients, other HCWs, or fomites. The Centers for Disease Control and Prevention (CDC) addressed this concern by designing a protocol to minimize contamination to the wearer during PPE removal (Figure 1) (6). However, the effectiveness of this protocol in preventing self-contamination has not been validated. To determine if removing PPE according to the CDC protocol prevents viral contamination of the wearer, a human challenge study was undertaken using a nonpathogenic virus.

The Study

PPE (gowns, gloves, respirators, and goggles) donned by volunteers was contaminated with bacteriophage MS2, a nonenveloped, nonpathogenic RNA virus suspended in 0.01 mol/L phosphate-buffered saline and GloGerm (GloGerm, Moab, UT, USA), synthetic beads that fluoresce under UV light (for visual tracking of virus). Sites of contamination were as follows: front shoulder of gown, back shoulder of gown, right side of N95 respirator, upper right front of goggles, and palm of dominant hand. Each site was contaminated with a total of 104 PFU of MS2 in 5 drops of 5 μL each. Participants performed a healthcare task (measuring blood pressure on a mannequin) and then removed PPE according to CDC protocol. Hands, items of PPE, and scrubs worn underneath were sampled for virus. Hands were sampled by using the glove juice method (7). Each hand was placed inside a bag containing 75 mL stripping solution (0.4 g KH2PO4, 10.1 g Na2HPO4, 1.0 mL Triton-X/L) and massaged for 60 seconds to cover all hand surfaces with solution. PPE items were immersed in 1.5% beef extract, pH 7.5, and agitated on a shaker for 20 minutes. Eluent from hands and PPE was assayed by the most probable number (MPN) enrichment infectivity assay (8). To prevent cross-contamination, samples from only 1 volunteer were processed at a time, and individual eluent samples were processed separately in a biological safety cabinet, with decontamination in between.

Figure 2

Thumbnail of Figure 2 - Protocol for human challenge experiments. PPE, personal protective equipment; CDC, Centers for Disease Control and Prevention.

Figure 2. Protocol for human challenge experiments. PPE, personal protective equipment; CDC, Centers for Disease Control and Prevention.

When an a priori value of 25% was used for the 95% upper confidence limit when p (transfer) = 0, the sample size was N = 10. Protocols were approved by the University of North Carolina (UNC) Biomedical Institutional Review Board, and written informed consent was obtained. Enrolled participants met the following inclusion criteria: >18 years of age, nonpregnant, nonallergic to latex, no active skin disorders, and medical evaluation approval for N95 respirator fit testing and use (9). Experiments took place in a patient care room in the UNC Hospitals’ General Clinical Research Center. The experimental protocol is shown in Figure 2. Participants were shown the poster distributed by CDC (Figure 1) and given an opportunity to read it and ask questions. The poster was placed in front of the participants for reference while they donned and removed PPE.

Ten study participants were enrolled in this study: 9 women and 1 man. Nine participants were right-handed, and 1 was left-handed. Transfer of virus to both hands, the initially uncontaminated glove on the nondominant hand, and the scrub shirt and pants worn underneath the PPE was observed in most volunteers (Table). Because of the difficulty of sampling large facial areas, visible fluorescent tracer was used as the criterion to determine whether the face would be sampled. No tracer was observed on the facial areas of any volunteer. The fluorescent tracer was not a consistent indicator of virus contamination; virus was recovered both from sites where tracer was visible and where it was not detected.

The amount of virus recovered was 1–3 log10 MPN for hands and 1–4 log10 MPN for scrubs. The mean amount of virus recovered from the right hand (the dominant hand of 90% of volunteers) was greater than that recovered from the left hand. While removal of gloves and gowns required 2 hands, mask and goggle removal was one-handed, which could have resulted in larger quantities of virus being transferred to the dominant hand during removal. In the single left-handed study participant, recovery of virus was greater from the left hand than the right (1.82 log10 vs. 0.98 log10 MPN). The mean amount of virus recovered from scrub shirts was significantly greater than that recovered from pants (p = 0.01), possibly because of contact with hands when the gown is pulled away from the shoulder during removal.

Conclusions

PPE is vital for protecting HCWs from occupationally acquired infection during patient care, particularly from droplet- or airborne-transmitted diseases. However, removing PPE after patient care without contaminating skin or clothes is important. Although PPE is usually worn only for short periods, viruses such as influenza (10) and SARS coronavirus (11) can survive for hours on surfaces, and viral infection can be spread by surface-to-hand (12) and hand-to-hand contact (13).

Developing and validating an algorithm for removing PPE that prevents contamination of the skin and clothes of HCWs are key to interrupting nosocomial transmission of infectious agents. These experiments demonstrate that the current CDC algorithm is insufficient to protect HCWs from contamination during PPE removal. However, options that might prevent such contamination do exist, including double gloving, use of surgical protocols for PPE removal, and PPE impregnated with an antimicrobial agent.

A double-glove removal sequence would begin with removal of the outer glove, followed by removal of goggles or face shield, gown, and respirator/mask, and finishing with removal of the inner glove followed by hand hygiene; handling of PPE with ungloved hands is avoided. Borrowing PPE protocols from surgery, in which the ends of gown sleeves are tucked underneath gloves during wear, might also reduce contamination. When the HCW is finished, goggles and respirator are removed first, and gown and gloves are then removed together by peeling off both at the same time, again avoiding handling PPE with ungloved hands. Finally, the use of PPE impregnated with antimicrobial agents might also reduce or eliminate contamination of skin and clothes.

This study also indicates the need for continued emphasis on hand hygiene. A barrier to improving hand hygiene compliance rates is the belief that gloves make hand hygiene unnecessary (14). This is contradicted by our study and others showing that organisms can spread from gloves to hands after glove removal (15). Even if double gloving is incorporated into protocols for PPE use, it is not a substitute for proper hand hygiene. Before these or other candidate methods are introduced into clinical practice, their impact on the safety of HCWs should be validated by testing with methods such as we have described.

Ms Casanova is a doctoral student in environmental health sciences at the University of North Carolina, Chapel Hill. Her research interests include the detection and fate of viruses in natural and human-built environments, and low-cost drinking water treatment technologies for developing countries.

Acknowledgments

We thank Maria Gergen for technical assistance.

This research was supported by the Centers for Disease Control and Prevention and by a grant (RR00046) from the General Clinical Research Centers program of the Division of Research Resources, National Institutes of Health.

References

  1. Centers for Disease Control and Prevention. Immunization of health-care workers: recommendations of the Advisory Committee on Immunization Practices (ACIP) and the Hospital Infection Control Practices Advisory Committee (HICPAC). MMWR Morb Mortal Wkly Rep. 1997;46(RR-18):142.PubMed
  2. Boyce JM, Pittet D. Guideline for hand hygiene in health-care settings: recommendations of the Healthcare Infection Control Practices Advisory Committee and the HICPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Infect Control Hosp Epidemiol. 2002;23(Suppl):S340. DOIPubMed
  3. Siegel J, Rhinehart E, Jackson M, Chiarello L; Healthcare Infection Control Practices Advisory Committee. Guideline for isolation precautions: preventing transmission of infectious agents in healthcare settings 2007 [cited 2007 Dec 31]. Available from http://www.cdc.gov/ncidod/dhqp/pdf/guidelines/Isolation2007.pdf
  4. Chan-Yeung M. Severe acute respiratory syndrome (SARS) and healthcare workers. Int J Occup Environ Health. 2004;10:4217.PubMed
  5. Lau JTF, Fung KS, Wong TW, Kim JH, Wong E, Chung S, SARS transmission among hospital workers in Hong Kong. Emerg Infect Dis [serial online] 2003 Feb [cited 2007 Dec]. Available from http://www.cdc.gov/ncidod/EID/vol10no2/03-0534.htm
  6. Centers for Disease Control and Prevention. Sequence for donning and removing personal protective equipment (ppe). 2004 [cited 2007 Jan 21]. Available from http://www.cdc.gov/ncidod/sars/ic.htm
  7. American Society for Testing and Materials. Standard test method for evaluation of health care professional handwash formulation (method e 1174–94). West Conshohocken (PA): The Society; 1994.
  8. Environmental Protection Agency. Method 1601: male-specific (F+) and somatic coliphage in water by two-step enrichment procedure. 2001 [cited 2008 Jan 17]. Available from http://www.epa.gov/nerlcwww/1601ap01.pdf
  9. Respiratory Protection. 29 C.ER § 1910.134 (1998) [cited 2008 Jan 6]. Available from http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=12716
  10. Bean B, Moore BM, Sterner B, Peterson LR, Gerding DN, Balfour HH Jr. Survival of influenza viruses on environmental surfaces. J Infect Dis. 1982;146:4751.PubMed
  11. Rabenau HF, Cinatl J, Morgenstern B, Bauer G, Preiser W, Doerr HW. Stability and inactivation of SARS coronavirus. Med Microbiol Immunol (Berl). 2005;194:16. DOI
  12. Gwaltney JM Jr, Hendley JO. Transmission of experimental rhinovirus infection by contaminated surfaces. Am J Epidemiol. 1982;116:82833.PubMed
  13. Gwaltney JM, Moskalski PB, Hendley JO. Hand-to-hand transmission of rhinovirus colds. Ann Intern Med. 1978;88:4637.PubMed
  14. Pittet D. Improving adherence to hand hygiene practice: a multidisciplinary approach. Emerg Infect Dis. 2001;7:23440.PubMed
  15. Doebbeling BN, Pfaller MA, Houston AK, Wenzel RP. Removal of nosocomial pathogens from the contaminated glove. Implications for glove reuse and handwashing. Ann Intern Med. 1988;109:3948.PubMed

Figures

Table

Suggested citation for this article: Casanova L, Alfano-Sobsey E, Rutala WA, Weber DJ, Sobsey M. Virus transfer from personal protective equipment to healthcare employees’ skin and clothing. Emerg Infect Dis [serial on the Internet]. 2008 Aug [date cited]. Available from http://wwwnc.cdc.gov/eid/article/14/8/08-0085.htm

DOI: 10.3201/eid1408.080085

Top of Page

Table of Contents – Volume 14, Number 8—August 2008

Comments to the Authors

Please use the form below to submit correspondence to the authors or contact them at the following address:

Mark Sobsey, Environmental Sciences and Engineering; CB# 7431 McGavran-Greenberg, University of North Carolina, Chapel Hill, NC 27599, USA;





characters(s) remaining.

Comment submitted successfully, thank you for your feedback.

Comments to the EID Editors

Please contact the EID Editors via our Contact Form.

 

Past Issues

Select a Past Issue:

World Malaria Day - April 25, 2014 - Invest in the future, defeat malaria

Art in Science - Selections from Emerging Infectious Diseases
Now available for order



CDC 24/7 – Saving Lives, Protecting People, Saving Money. Learn More About How CDC Works For You…

USA.gov: The U.S. Government's Official Web PortalDepartment of Health and Human Services
Centers for Disease Control and Prevention   1600 Clifton Rd. Atlanta, GA 30333, USA
800-CDC-INFO (800-232-4636) TTY: (888) 232-6348 - Contact CDC–INFO