Volume 24, Number 7—July 2018
Dispatch
Legionnaires’ Disease Outbreak on a Merchant Vessel, Indian Ocean, Australia, 2015
Abstract
Two cases of Legionnaires’ disease and 1 of Pontiac fever occurred among the crew of a merchant ship operating off the shores of Australia. PCR assays identified potential sources in the ship’s cabins. Modification of maritime regulations for Legionnaires’ disease prevention in commercial vessels is needed for nonpassenger merchant ships.
The risk for Legionnaires’ disease (LD) is known on cruise liners (1–3) and is matched by recommendations for preventive measures (4,5). Environmental sources of Legionella pneumophila in ships are prone to transmit LD over several years through resistance to decontamination (6,7). As opposed to cruise liners, there are few reports of LD on working vessels, where occupational health risks differ (8). Legionella was detectable in potable water systems on 58% of 350 merchant vessels in a recent survey (9). There was no established precedent for environmental risk assessment or control when 2 LD cases occurred on a merchant ship off the northwestern Australian Indian Ocean coast in 2015. We therefore conducted an extended field investigation.
The first LD case-patient on the merchant ship sought treatment at the nearest hospital emergency department, and provided no alternative exposure source. After laboratory confirmation of this case, the crew disembarked and the vessel was required to lie at anchor offshore. After emergency control measures by a private contractor, we obtained information on the ship’s plumbing, including potable, fresh, and hot water systems, water storage, air conditioning; food preparation areas, and sleeping quarters.
We then boarded the ship for environmental investigation on August 27, 2015, to collect samples from potential fomites around the vessel at 33 locations, including cabins and potable water outlets. We collected PCR swab samples in duplicate from inside showerheads and sink faucets (also known as mixer taps) aerators in sleeping quarters and food preparation areas, including those used by LD case-patients and their neighbors. The contractor disinfected the water system by using super chlorination the next day, and collected a second environmental sample series on September 4. Additional targeted control measures included replacement of showerheads and removal of faucet aerators from cabins.
We collected a series of PCR swab samples from original test locations on October 12 to assess the residual health threat, and tested 24 of these samples on the ship (10). Duplicate samples were then tested in the reference laboratory (10). We analyzed showerheads removed from cabins (Figure 1). We tested samples of the inside surface of each showerhead and its O-ring gaskets by using PCR assays. We collected swab samples from potential reservoirs and tested for Legionella species: the O-rings; rinse samples from showerhead parts in sterile 0.08% NaCl solution for Legionella species; peptone water washings, showerhead contents, debris from a thermal mixing valve, fresh and pre–UV-treated water, showerheads, air conditioners, and faucets from cabins (11). We identified presumptive Legionella cultures on MWY and BMPA agars by using Legionella Latex Agglutination antisera (Oxoid; ThermoFisher Scientific Australia Pty Ltd, Scoresby, Melbourne, Victoria, Australia), and cultured for amoeba on showerhead rinse specimens. Detailed methods are provided in Technical Appendix Part 1.
In August 2015, the Western Australia Department of Health was notified of Legionnaires’ disease confirmed by L. pneumophila serogroup 1 urinary antigen test in a member of the vessel’s crew (case-patient 1), and was informed that other crew members had mild febrile respiratory illness (Table 1). Later that day, another crew member, who had symptoms of severe bilateral pneumonia and pneumothorax, arrived at the regional hospital and required aeromedical evacuation for intensive care (case-patient 2). LD was confirmed by urinary antigen testing and PCR assay on bronchial washings. Other crew members who had nonpneumonic respiratory and other symptoms were investigated for legionellosis by using urinary antigen tests and serologic tests which proved negative, except in case-patient 3, who had L. pneumophila seroconversion and Pontiac fever that did not require hospital admission. The 3 cases all satisfied Australian LD case definitions (12). Case-patients 1 and 2 occupied adjacent cabins and case-patient 3 was 2 cabins away from case-patient 2 (Figure 2).
L. pneumophila was not isolated from any environmental samples. Legionella PCR result was positive in 7/10 cabins tested (13/27 samples) (Table 2). A PCR result was positive for showerheads or residual water from sink faucets in the cabins of 2 LD cases. In 5 other cabins, only faucets were positive (Figure 2). Detection of sludge or biofilm in the shower heads and faucets prompted replacement with better-designed showerheads and removal of faucet aerators. Only 2/79 samples collected on the second visit on September 4 were Legionella PCR positive; a significant reduction (χ2, Yates’ correction; 15.98, p<0.001). Only 1 of the 58 samples from the third series of samples was clearly PCR positive, from a faucet in a cabin unconnected to LD cases. The in-field PCR results were identical to the confirmatory reference laboratory replicate results. All 10 types of showerhead were rust-stained inside and smelled of chlorine. The most common showerhead types had either 7 silicone rubber O-rings or 1 complex silicone rubber gasket. Showerhead swabs and agar O-ring impressions grew profuse mixed bacteria, commonly Pseudomonas aeruginosa. Nonpneumophila Legionella sp. was isolated from 1 showerhead. Legionella PCR assays produced unambiguous positives in 13/16 showerheads (19/32 samples). Almost all O-rings from the common showerhead types were Legionella positive (Technical Appendix Part 2).
A recent study of nonpassenger merchant vessels (NPMVs) highlighted the risk for Legionella contamination of potable water systems (9), but did not establish a link with confirmed infections. Our investigation of L. pneumophila serogroup 1 infection in a merchant vessel’s crew highlights the need to control Legionella in NPMV water systems, and the challenge of using PCR assays, which do not detect viable bacteria. Culture-dependent methods did not contribute to determination of the environmental source or route of dissemination. Preliminary control measures by external contractors may have prevented Legionella isolation from our environmental samples, but have doubtful long-term preventive value without sustained control measures because environmental persistence occurs in ships despite biocide treatment (6).
The survey vessel had a gross tonnage of 2,620, was 64 m long, 16 m wide, a draft of 4.7 m, and a crew of 27. It had 2 water storage tanks with 60,000 L capacity, an ultraviolet water sterilization unit, and 2 hot water geysers. These tanks were refilled from bunkers while in port, and replenished at sea by reverse osmosis. Showers were highlighted in a previous study of NPMV potable water systems (9), and aerator devices have been implicated as bacterial amplification sites in tropical and nosocomial outbreaks (13,14).
Multiple positive PCR results from water outlets in the cabins implicated the showers and faucets as means of infection. All showerheads on the vessel had interior moving parts to control spray settings and were the leading PCR-positive location. A rust-colored biofilm inside most showerheads indicated possible deterioration of iron pipes in the ship’s distribution system, and persistence of Legionella in biofilms (15). The silicone rubber O-rings from the showerheads supported profuse growth of aquatic bacteria and were PCR positive for L. pneumophila. The O-rings formed a permanently wet niche for bacterial growth, and their movement will shear bacteria from biofilms. Faucet aerators also promote turbulent flow by mixing water and air under pressure. These results highlight the potential for Legionella aerosol generation. We recommended replacing the showerheads with a simpler plastic design, more suited to periodic removal, decontamination, and cleaning, and gravity drainage after daily use.
A cluster of L. pneumophila serogroup 1 infections in a vessel working in waters near Australia led to an environmental health assessment in which molecular methods enabled the field investigation team to implicate water outlets in crew quarters and tailor environmental controls. Deployment of quantitative PCR assays extended our investigative reach offshore, enabling faster return of the vessel to active service. The leadership and crew of nonpassenger merchant vessels operating in tropical waters need heightened Legionella awareness and require control measures more stringent than those applied in passenger vessels.
Dr. Inglis is a medical and public health microbiologist at PathWest Laboratory Medicine WA, Nedlands, Western Australia, who has worked on emerging infectious diseases in Western Australia since 1997. His research interests include bioreconnaissance, melioidosis, and emerging antimicrobial resistance.
Acknowledgments
The authors thank their colleagues in the Department of Microbiology, PathWest Laboratory Medicine WA, the Shire of Broome, Kimberley Population Health, the Environmental Health Directorate, WA Department of Health, the Department of Infectious Diseases, Sir Charles Gairdner Hospital, and the Communicable Disease Control Directorate, WA Department of Health for their assistance with this investigation.
T.J.J.I. and R.J.M. managed the patients and the corresponding clinical laboratory investigations. T.J.J.I. initiated the public health laboratory investigation in collaboration with G.K.D., who coordinated the public health response to the outbreak, liaised with the shipping company, maritime authorities, and regional public health unit. C.S. assisted with environmental specimen collection from the start of the investigation and collected subsequent PCR sample series with the support of H.C. The first boarding party comprised T.J.J.I., C.S., and J.D., who together collected, documented, secured, and forwarded environmental samples and their contextual data. M.C. and A.M. M. conducted the environmental bacteriology, in consultation with and under the guidance of M.H. T.J.J.I. conducted the Legionella PCR assays in the field. A.J.M. verified these in the reference laboratory and conducted the additional PCR analyses. T.J.J.I. collated input from the other authors and wrote the first draft, which was then edited by A.J.M. and G.K.D. before circulation to the other authors. All authors have contributed to this report, and have reviewed and checked its content for accuracy.
References
- Centers for Disease Control and Prevention (CDC). Cruise-ship—associated Legionnaires disease, November 2003-May 2004. MMWR Morb Mortal Wkly Rep. 2005;54:1153–5.PubMedGoogle Scholar
- Azara A, Piana A, Sotgiu G, Dettori M, Deriu MG, Masia MD, et al. Prevalence study of Legionella spp. contamination in ferries and cruise ships. BMC Public Health. 2006;6:100. DOIPubMedGoogle Scholar
- Goutziana G, Mouchtouri VA, Karanika M, Kavagias A, Stathakis NE, Gourgoulianis K, et al. Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries. BMC Public Health. 2008;8:390. DOIPubMedGoogle Scholar
- Mouchtouri VA, Rudge JW. Legionnaires’ disease in hotels and passenger ships: a systematic review of evidence, sources, and contributing factors. J Travel Med. 2015;22:325–37. DOIPubMedGoogle Scholar
- Mouchtouri VA, Bartlett CL, Diskin A, Hadjichristodoulou C. Water Safety Plan on cruise ships: a promising tool to prevent waterborne diseases. Sci Total Environ. 2012;429:199–205. DOIPubMedGoogle Scholar
- Ahlen C, Aas M, Krusnell J, Iversen O-J. A single Legionella pneumophila genotype in the freshwater system in a ship experiencing three separate outbreaks of legionellosis in 6 years. Microb Ecol Health Dis. 2016;27:31148.PubMedGoogle Scholar
- García MT, Baladrón B, Gil V, Tarancon ML, Vilasau A, Ibañez A, et al. Persistence of chlorine-sensitive Legionella pneumophila in hyperchlorinated installations. J Appl Microbiol. 2008;105:837–47. DOIPubMedGoogle Scholar
- Ahlén C, Aas M, Nor A, Wetteland PI, Johansen H, Sørbø T, et al. Legionella pneumophila in Norwegian naval vessels. Tidsskr Nor Laegeforen. 2013;133:1445–8.PubMedGoogle Scholar
- Collins SL, Stevenson D, Mentasti M, Shaw A, Johnson A, Crossley L, et al. High prevalence of Legionella in non-passenger merchant vessels. Epidemiol Infect. 2017;145:647–55. DOIPubMedGoogle Scholar
- Lindsay DS, Abraham WH, Fallon RJ. Detection of mip gene by PCR for diagnosis of Legionnaires’ disease. J Clin Microbiol. 1994;32:3068–9.PubMedGoogle Scholar
- Standards Australia. Waters – Examination for Legionella species including Legionella pneumophila. Australia/New Zealand Standard Method 3896:2008. https://infostore.saiglobal.com/preview/as/as3000/3800/3896-2017.pdf?sku=1912444 [cited 10/12/2017]
- Legionellosis case definition. Department of Health, Government of Australia. http://www.health.gov.au/internet/main/publishing.nsf/Content/cda-surveil-nndss-casedefs-cd_legion.htm 12/20/2012 [cited 10/12/2017]
- Inglis TJ, Benson KA, O’Reilly L, Bradbury R, Hodge M, Speers D, et al. Emergence of multi-resistant Pseudomonas aeruginosa in a Western Australian hospital. J Hosp Infect. 2010;76:60–5. DOIPubMedGoogle Scholar
- Inglis TJ, Garrow SC, Henderson M, Clair A, Sampson J, O’Reilly L, et al. Burkholderia pseudomallei traced to water treatment plant in Australia. Emerg Infect Dis. 2000;6:56–9.PubMedGoogle Scholar
- van der Lugt W, Euser SM, Bruin JP, Den Boer JW, Walker JT, Crespi S. Growth of Legionella anisa in a model drinking water system to evaluate different shower outlets and the impact of cast iron rust. Int J Hyg Environ Health. 2017;220:1295–308. DOIPubMedGoogle Scholar
Figures
Tables
Cite This ArticleTable of Contents – Volume 24, Number 7—July 2018
EID Search Options |
---|
Advanced Article Search – Search articles by author and/or keyword. |
Articles by Country Search – Search articles by the topic country. |
Article Type Search – Search articles by article type and issue. |
Please use the form below to submit correspondence to the authors or contact them at the following address:
Timothy J.J. Inglis, PathWest Laboratory Medicine, Department of Microbiology, Locked Bag 2009, Western Australia, QE2 Medical Centre, Nedlands, WA 6009, Australia
Top