Volume 28, Number 12—December 2022
Research Letter
Laboratory Features of Trichinellosis and Eosinophilia Threshold for Testing, Nunavik, Quebec, Canada, 2009–2019
Figure

Figure. Receiver operating characteristic curve comparing performance of thresholds of absolute and relative eosinophilia to trigger automatic reporting of possible trichinellosis. Sn and Sp for the thresholds of absolute eosinophilia examined were 0.5 × 109 (Sn = 1.0, Sp = 0.65), 0.8 × 109 (Sn = 1.0, Sp = 0.71), 1.0 × 109 (Sn = 0.91, Sp = 0.71), 2.0 × 109 (Sn = 0.63, Sp = 0.94) and for relative eosinophilia were 5% (Sn = 1.0, Sp = 0.65), 10% (Sn = 0.88, Sp = 0.71), 15% (Sn = 0.85, Sp = 0.76), and 30% (Sn = 0.36, Sp = 1.0). Sn, sensitivity; Sp, specificity.