Case of Legionella pneumophila Serogroup 1 Infection Linked to Water Flosser, France

Author affiliation: Centre Hospitalier Universitaire, Besançon, France (C. Slekovec, A. Biguenet, A. Jeanvoine, D. Hocquet, X. Bertrand); Université Marie et Louis Pasteur, Besançon (C. Slekovec, A. Biguenet, D. Hocquet, X. Bertrand).

Suggested citation for this article

Abstract

Legionnaires’ disease is a severe respiratory infection that causes increased mortality in hospitalized and immunocompromised patients. We report a nosocomial case in France linked to a water flosser. Our findings underscore the need for vigilance regarding such devices and highlight strategies for their safe management within healthcare settings.

Legionnaires’ disease is a respiratory infection caused by inhaling particles contaminated with Legionella spp. bacteria (1). Although most cases are community-acquired, mortality is nearly 3 times higher for hospital-acquired infections (8.6% vs. 28.6%) (2), especially among immunocompromised patients (3). This increase in mortality underscores the need for routine monitoring of water systems and the use of protective measures such as point-of-use filters. Environmental investigations are critical for identifying sources of contamination; however, whereas healthcare facilities have the infrastructure to conduct such investigations, implementation in private homes remains challenging. Of consequence, extra-hospital sources of exposure are likely underrecognized. In this article, we describe a case of nosocomial Legionnaires’ disease traced to a water flosser from the patient’s home.

The Study

A 48-year-old man with IgG Kappa myeloma was hospitalized in August 2024 for a peripheral autologous hematopoietic stem cell transplantation in the hematology unit of Besançon University Hospital (Besançon, France). On day 4, the patient underwent an autograft without complications. On day 10, a fever developed, and Escherichia coli was isolated from blood cultures. We began piperacillin/tazobactam (4 g every 6 hours) therapy adapted to the strain resistance profile, and the following blood cultures were negative. However, the fever persisted, and respiratory symptoms developed on day 16. His condition worsened on day 17, and we transferred the patient to the medical intensive care unit (MICU). At admission in MICU, results of a BinaxNOW Legionella urinary antigen test for Legionella pneumophila serogroup 1 (Lp1) (Abbott, https://www.abbott.com) were positive. The same day, we detected Lp1 by using PCR on bronchoalveolar samples and cultured endotracheal aspiration samples. No tests for Legionella spp. were conducted before day 17. The respiratory distress syndrome caused by pneumonia led to a stay in MICU with mechanical ventilation, dialysis, and cardiorespiratory arrest without sequelae. The patient experienced multiple organ failure with acute renal failure requiring extrarenal purification. Complications including necrosis of the extremities, sacral pressure ulcer, malnutrition, and amyotrophy developed. His condition gradually improved, enabling his discharge from MICU after 47 days.

Because the incubation period was consistent with acquisition in the hematology unit, we searched for environmental sources of Legionella spp. During his hospitalization in the unit, the patient stayed in a room intended for immunocompromised patients, and the sink and shower were equipped with the Filt’Ray 2G anti-Legionella filters (Aquatools, https://www.aqua-tools.com). We took water samples from the bathroom in the patient’s room (sink and shower with and without filter and the toilet bowl).

We analyzed samples in accordance with the NF T 90-431 standard (Association Française de Normalization, https://www.afnor.org) for counting Legionella spp. We sampled 500 mL of water in sterile vials containing 20 mg sodium thiosulfate. First, we inoculated 0.2 mL of water on glycine, vancomycin, polymyxin, cycloheximide plates (Thermo Fisher Scientific, https://www.thermofisher.com). Then, we filtered 10 mL and 100 mL of water through 0.2-µm pore polycarbonate membranes placed on glycine, vancomycin, polymyxin, cycloheximide media. We incubated the plates at 36°C (+2°C) for 8–11 days. We subcultured suspicious colonies to buffered charcoal yeast extract media with and without cystein and identified them by using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (Bruker, https://www.bruker.com).

Figure

Timeline of patient hospitalization, symptoms, and tests performed in a case of Legionella pneumophila serogroup 1 infection linked to water flosser, France. D, day; Lp1, Legionella pneumophila serogroup 1; Lp2–14, Legionella pneumophila serogroups 2–14; MICU, medical intensive care unit; ST, sequence type; +, positive.

Figure. Timeline of patient hospitalization, symptoms, and tests performed in a case of Legionella pneumophila serogroup 1 infection linked to water flosser, France. D, day; Lp1, Legionella pneumophila...

We tested the mixed water from the sink and shower (with the filter and after removing the filter) and the toilet bowl water and did not find evidence of Legionella spp. In addition, the 10 routine tests conducted in 2024 on the water network supplying the ward were also all negative for Legionella spp. During the environmental investigation, a water flosser (Panasonic, https://www.panasonic.com) was found in the patient’s bathroom. This device was not listed in the inventory performed at admission to the hematology department. The device belonged to the patient, which he used at home with tap water, and it was brought in without informing the healthcare team. Because the patient was unable to be interviewed, we were unable to gather information on the use of the device (i.e., frequency of use during hospitalization, type of water used, frequency of cleaning and disinfection). To sample the water flosser, we filled its tank with sterile water, ran the device, and collected 100 ml of water from the jet. We recovered Lp1 and L. pneumophila serogroup 2–14 at a concentration of 300 CFU/L (Figure).

We sequenced the genomes of the 2 Lp1 isolates (1 from the patient and 1 from the water flosser) by using Oxford Nanopore technology (Oxford Nanopore, https://nanoporetech.com). We assembled genomes by using Flye (4) and deduced sequence types from whole-genome sequencing data by using legsta (https://github.com/tseemann/legsta). The 2 strains had identical genomes and belonged to sequence type 42, which has been described in France and other countries but is not a major clone (5).

Our investigation indicates it is likely the clinical strain and the Lp1 strain identified from the water flosser have a common origin. After this incident, no new cases have been reported in our hospital. The patient was ultimately hospitalized for 62 days, including 47 days in MICU.

Conclusions

We report a case of Legionnaires’ disease transmitted by a contaminated water flosser. This conclusion was supported by the genomic identity of Lp1 isolates recovered from the patient and water flosser. The other commonly suspected sources, such as shower or sink, or less common, such as toilet (6,7), were negative for Legionella spp. The Legionella spp. found in the device (including Lp1, responsible for infection, and L. pneumophila serogroup 2–14) likely originated from the patient’s home water network. Unfortunately, no investigation could be conducted to confirm that suspicion. Moreover, the reservoir of the device showed signs of fouling, indicative of the use of nonsterile water and the lack of regular cleaning. Most manufacturers do not advocate for the use of sterile or microbiologically controlled water; instead, they recommend regular cleaning and disinfection procedures. The global water flosser market is experiencing growth ($966.726 million in 2021, projected to reach $1,189 million by 2025), driven by increased awareness of oral hygiene, a growing preference for wireless and portable devices, and guidelines issued by oral health professionals (8). Because of the increasing use of such devices, a growing number of immunocompromised patients at risk of Legionnaires’ disease could be exposed. We did not find other cases of contamination through water flossers reported in the literature, indicating a low risk; nevertheless, unrecognized cases cannot be excluded.

Water flossers might provide favorable conditions for bacterial growth, especially Legionella spp. The use of nonsterile water can lead to biofilm accumulation within the device tubing. In addition, the pressurized spray directed into the patient’s mouth may generate aerosols that are readily inhaled. Several studies have demonstrated bacterial colonization of water flossers and the potential transmission of contaminated water jets; in particular, colonization by the major caries-associated pathogen Streptococcus mutans appears difficult to prevent (9,10). Therefore, it is necessary to raise awareness among manufacturers and users regarding the potential risk to immunocompromised patients. In healthcare settings, the use of such devices should be carefully controlled to prevent nosocomial Legionnaires’ disease, and healthcare workers should be aware of the potential risk of devices being brought from the outside into healthcare settings by patients or family members. Our report demonstrates that despite all the measures implemented in hospitals to control the risk for Legionella spp. transmission to immunocompromised patients, attention should be paid to unconventional modes of Legionella spp. transmission.

Dr. Slekovec is a pharmacist specializing in infection prevention and control at the University Hospital of Besançon, France. His research focuses on improving the prevention of healthcare-associated infections, particularly those related to waterborne pathogens such as Legionella pneumophila and Pseudomonas aeruginosa.

Top

Acknowledgments

We thank the healthcare teams and all those who contributed to the investigation of this case. We also acknowledge the patient for his cooperation.

The study was approved by the Institutional Review Board of Besançon University Hospital and conducted in accordance with the principles of the Declaration of Helsinki. Patients were informed about the use of their data during hospitalization and had the right to refuse participation in the study.

Top

References

  1. Rello  J, Allam  C, Ruiz-Spinelli  A, Jarraud  S. Severe Legionnaires’ disease. Ann Intensive Care. 2024;14:51. DOIPubMedGoogle Scholar
  2. Beauté  J, Plachouras  D, Sandin  S, Giesecke  J, Sparén  P. Healthcare-Associated Legionnaires’ Disease, Europe, 2008-2017. Emerg Infect Dis. 2020;26:230918.PubMedGoogle Scholar
  3. Francois Watkins  LK, Toews  KE, Harris  AM, Davidson  S, Ayers-Millsap  S, Lucas  CE, et al. Lessons from an outbreak of Legionnaires’ disease on a hematology-oncology unit. Infect Control Hosp Epidemiol. 2017;38:30613. DOIPubMedGoogle Scholar
  4. Kolmogorov  M, Yuan  J, Lin  Y, Pevzner  PA. Assembly of long, error-prone reads using repeat graphs. Nat Biotechnol. 2019;37:5406. DOIPubMedGoogle Scholar
  5. Pijnacker  R, Brandsema  P, Euser  S, Vahidnia  A, Kuiter  A, Limaheluw  J, et al. An outbreak of Legionnaires’ disease linked to a municipal and industrial wastewater treatment plant, The Netherlands, September-October 2022. Euro Surveill. 2024;29:2300506. DOIPubMedGoogle Scholar
  6. Couturier  J, Ginevra  C, Nesa  D, Adam  M, Gouot  C, Descours  G, et al. Transmission of Legionnaires’ disease through toilet flushing. Emerg Infect Dis. 2020;26:15268. DOIPubMedGoogle Scholar
  7. Bechmann  L, Bauer  K, Zerban  P, Esser  T, Tersteegen  A, Fuchs  SA, et al. Prevention of legionella infections from toilet flushing cisterns. J Hosp Infect. 2024;146:3743. DOIPubMedGoogle Scholar
  8. Zarei  Z, Yazdi  M, Sadeghalbanaei  L, Tahamtan  S. The effectiveness of oral irrigators on periodontal health status and oral hygiene of orthodontic patients: a systematic review and meta-analysis. BMC Oral Health. 2024;24:1469. DOIPubMedGoogle Scholar
  9. Bertl  K, Geissberger  C, Zinndorf  D, Johansson  PE, Al-Shammari  H, Eick  S, et al. Bacterial colonisation during regular daily use of a power-driven water flosser and risk for cross-contamination. Can it be prevented? Clin Oral Investig. 2022;26:190313. DOIPubMedGoogle Scholar
  10. Bertl  K, Edlund Johansson  P, Bruckmann  C, Leonhard  M, Davies  JR, Stavropoulos  A. Bacterial colonization of a power-driven water flosser during regular use. A proof-of-principle study. Clin Exp Dent Res. 2021;7:65663. DOIPubMedGoogle Scholar

Top

Figure

Top

Suggested citation for this article: Slekovec C, Biguenet A, Jeanvoine A, Hocquet D, Bertrand X. Case of Legionella pneumophila serogroup 1 infection linked to water flosser, France. Emerg Infect Dis. 2026 Feb [date cited]. https://doi.org/10.3201/eid3202.251386

DOI: 10.3201/eid3202.251386

Original Publication Date: February 15, 2026

Table of Contents – Volume 32, Number 2—February 2026

EID Search Options
presentation_01 Advanced Article Search – Search articles by author and/or keyword.
presentation_01 Articles by Country Search – Search articles by the topic country.
presentation_01 Article Type Search – Search articles by article type and issue.

Top

Comments

Please use the form below to submit correspondence to the authors or contact them at the following address:

Xavier Bertrand, Hygiène Hospitalière, Centre Hospitalier Universitaire, 3 boulevard Fleming, Besançon CEDEX 25030, France

Send To

10000 character(s) remaining.

Top

Page created: January 29, 2026
Page updated: February 15, 2026
Page reviewed: February 15, 2026
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.
file_external