Author affiliations: *National Taiwan University College of Medicine, Taipei, Taiwan; †Tsu Chi University, Hualien, Taiwan; ‡Academia Sinica, Taipei, Taiwan; §United Biomedical, Inc., Hauppauge, New York, USA; ¶United Biomedical, Inc. Asia, Hsin Chu, Taiwan; 1Drs. Hsueh and Kao contributed equally to this article.

Main Article

Table 1

Sensitivity of peptide-based SARS-CoV ELISA from two patients at NTUa

Patient/day A450nm S/C ratio
SARS patient 1
  Day 0 0.119 0.44
  Day 11 1.638 6.09
  Day 17 2.447 9.10
  Day 38 2.749 10.22
  Day 97 2.600 9.67
SARS patient 2
  Day 0 0.068 0.25
  Day 6 0.163 0.61
  Day 16 0.345 1.28
  Day 27 1.212 4.51
  Day 116 >3.000 >9.40

aSARS, severe acute respiratory syndrome; CoV, coronavirus; ELISA, enzyme-linked immunosorbent assay; S/C = signal/cutoff ratio; NTU, National Taiwan University.

Main Article

Page created: March 29, 2011
Page updated: March 29, 2011
Page reviewed: March 29, 2011
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.