Skip directly to site content Skip directly to page options Skip directly to A-Z link Skip directly to A-Z link Skip directly to A-Z link
Volume 27, Number 11—November 2021
Synopsis

Effectiveness of Abbott BinaxNOW Rapid Antigen Test for Detection of SARS-CoV-2 Infections in Outbreak among Horse Racetrack Workers, California, USA

Krishna SurasiComments to Author , Kristin J. Cummings, Carl Hanson, Mary Kate Morris, Maria Salas, David Seftel, Liza Ortiz, Ruwan Thilakaratne, Cameron Stainken, and Debra A. Wadford
Author affiliations: Centers for Disease Control and Prevention, Atlanta, Georgia, USA (K. Surasi); California Department of Public Health, Richmond, California, USA (K. Surasi, K.J. Cummings, C. Hanson, M.K. Morris, M. Salas, R. Thilakaratne, C. Stainken, D.A. Wadford); Golden Gate Fields, Berkeley, California, USA (D. Seftel); City of Berkeley Public Health Officer Unit, Berkeley (L. Ortiz); Kaiser Permanente San Francisco Internal Medicine Residency Program, San Francisco, California, USA (C. Stainken); University of California San Francisco School of Medicine, San Francisco (C. Stainken).

Main Article

Figure 1

Concordance of BinaxNOW rapid antigen test results with positive rRT-PCR results over 6 testing rounds among staff at a horse racetrack, California, USA, November–December 2020. All rRT-PCR–negative results (n = 642) were concordant with BinaxNOW results, so only rRT-PCR–positive results (n = 127) are shown. Crossbars represent mean Ct for the concordant and discordant pair groups in each testing period. The dashed line represents Ct = 30. Ct, cycle threshold; rRT-PCR, real-time reverse transcription PCR.

Figure 1. Concordance of BinaxNOW rapid antigen test results with positive rRT-PCR results over 6 testing rounds among staff at a horse racetrack, California, USA, November–December 2020. All rRT-PCR–negative results (n = 642) were concordant with BinaxNOW results, so only rRT-PCR–positive results (n = 127) are shown. Crossbars represent mean Ct for the concordant and discordant pair groups in each testing period. The dashed line represents Ct = 30. Ct, cycle threshold; rRT-PCR, real-time reverse transcription PCR.

Main Article

Page created: August 18, 2021
Page updated: October 19, 2021
Page reviewed: October 19, 2021
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.