Skip directly to site content Skip directly to page options Skip directly to A-Z link Skip directly to A-Z link Skip directly to A-Z link
Volume 28, Number 1—January 2022
Dispatch

Transfusion-Transmitted Hepatitis A Virus, France, 2018

Caroline LefeuvreComments to Author , Caroline Lefort, Françoise Boyer, Sophie Le Cam, Lina Mouna, Anne-Marie Roque-Afonso, Hélène Le Guillou-Guillemette, and Rafaël Mahieu
Author affiliations: Angers University Hospital, Angers, France (C. Lefeuvre, F. Boyer, H. Le Guillou-Guillemette, R. Mahieu); University of Angers, Angers (C. Lefeuvre, H. Le Guillou-Guillemette, R. Mahieu); Etablissement Français du Sang Centre-Pays de la Loire, Angers (C. Lefort, S. Le Cam); University of Paris–Saclay, Villejuif, France (L. Mouna, A.-M. Roque-Afonso); French National Reference Center for Hepatitis A Virus, Villejuif (L. Mouna, A.-M. Roque-Afonso)

Main Article

Table

Laboratory results from donor plasma and recipient serum in case of transfusion-transmitted HAV, France, 2018*

Source Sample date HAV test result (s/c)
HAV avidity index, %† HAV RNA, log10 IU/mL ALT, IU/L
IgM IgG
Donor 2018 Jun 23 NR‡ NR§ ND <1.00 ND
Donor¶ 2018 Aug 28 NR‡ NR§ ND 5.43# ND
Recipient 2018 Jun 25 NR** NR†† ND ND 49
Recipient¶ 2018 Oct 25 R** (2.35) R†† (3.73) 12.95 5.82 3,553
Recipient 2018 Oct 30 ND ND ND ND 1,200
Recipient 2018 Nov 9 ND ND ND ND 144
Recipient 2018 Nov 19 ND ND 31.85 3.42 ND
Recipient 2018 Dec 10 ND ND 39.15 3.14 59
Recipient 2019 Jan 17 ND ND 44.00 <1.00 39

*ALT, alanine aminotransferase; HAV, hepatitis A virus; ND, test not done; NR, nonreactive; R, reactive; s/c, sample/cutoff ratio. †HAV avidity index was expressed as a percentage as follows: HAV avidity index = (the absorbance reading with urea wash/the absorbance reading without urea wash) × 100. Avidity index <50% indicates acute infection. ‡VIDAS Anti-HAV IgM (bioMérieux, https://www.biomerieux.com). Value >0.5 is considered reactive. §Elecsys Anti-HAV total antibodies (value >22 mIU/mL considered reactive) ¶Genotype IA was identified. #Result (log10 IU/mL) corresponds to HAV RNA quantification performed at the National Reference Center for HAV. The result of qualitative detection performed at the French National Blood Service was 3.27 (no unit). **ARCHITECT HAV Ab-IgM (Abbott Diagnostics, https://www.diagnostics.abbott). Value >1.20 is considered reactive. ††ARCHITECT HAV Ab-IgG (Abbott Diagnostics). Value >1.00 is considered reactive.

Main Article

Page created: November 30, 2021
Page updated: December 20, 2021
Page reviewed: December 20, 2021
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.
file_external