Volume 28, Number 11—November 2022
Research
Fungal Endophthalmitis Outbreak after Cataract Surgery, South Korea, 2020
Table 3
Brand of OVD |
No. cases† |
No. surgeries |
Incidence risk per 100,000 population |
Risk ratio (95% CI) |
---|---|---|---|---|
Company A OVD | 152 | 49,193 | 309.0 | 86.0 (27.4–269.7) |
Other OVDs, referent | 3 | 83,554 | 3.6 |
*OVD, ophthalmic viscoelastic device. †Among 156 total cases; excludes 1 case that used an OVD without sufficient database information.
1These first authors contributed equally to this work.
Page created: October 01, 2022
Page updated: October 21, 2022
Page reviewed: October 21, 2022
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.