HEPA/Vaccine Plan for Indoor Anthrax Remediation

Lawrence M. Wein*Comments to Author , Yifan Liu*, and Terrance J. Leighton†
Author affiliations: *Stanford University, Stanford, California, USA; †Children's Hospital Oakland Research Institute, Oakland, California, USA

Main Article

Figure 4

Performance of the HEPA/vaccine plan under the base-case scenario. The horizontal axes in plots A-C are the number of floor samples per round (). Each of plots A–C have 4 curves, 1 for each value of the floor concentration threshold (). Cleaning stops after the estimated floor concentration from samples per room is below the threshold . The vertical axes in plots A-C are A) the mean number of inhalation anthrax cases, B) the mean cost, and C) the mean recovery time. In plots A-C, the concentrati

Figure 4. . . Performance of the HEPA/vaccine plan under the base-case scenario. The horizontal axes in plots A-C are the number of floor samples per round (). Each of plots A–C have 4 curves, 1 for each value of the floor concentration threshold (). Cleaning stops after the estimated floor concentration from samples per room is below the threshold . The vertical axes in plots A-C are A) the mean number of inhalation anthrax cases, B) the mean cost, and C) the mean recovery time. In plots A-C, the concentration threshold () has a much bigger impact than the number of samples per room () on these 3 performance measures. Plot D shows the tradeoff of anthrax cases versus recovery time in the base case. The number of samples per room is assumed to be = 1 in this plot, which is derived from plots A–C. Plot D also contains tradeoff curves for 3 sensitivity analyses: a lower air-cleaning rate, increased sampling variability of spore concentration, and the most severe of the 92 cases depicted in Figure 3B. This plot shows that the cases versus time tradeoff curve is very insensitive to changes in the air-cleaning rate and sampling variability.

Main Article

Page created: April 25, 2012
Page updated: April 25, 2012
Page reviewed: April 25, 2012
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.
file_external