Author affiliations: Erasmus MC, Rotterdam, the Netherlands (Z. Igloi, J. Velzing, J. van Beek, D. van de Vijver, G. Aron, M. Koopmans, C. Geurtsvankessel, R. Molenkamp); Public Health Service Rotterdam-Rijnmond, Rotterdam (R. Ensing, T. Boelsums); National Public Health Institute (RIVM), Bilthoven, the Netherlands (K. Benschop, W. Han)

Main Article

Table 2

Overview of results of comparison of rapid antigen test and PCR for severe acute respiratory syndrome coronavirus 2, the Netherlands*

Ag RDT result PCR result
Total
Positive Negative
Positive 158 4 162
Negative 28 780 808
Total 186 784 970

*Ag RDT, rapid antigen detection test.

Main Article

Page created: March 16, 2021
Page updated: April 20, 2021
Page reviewed: April 20, 2021
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.