Environmental and Occupational Health Response to SARS, Taiwan, 2003
Table 2
Hospital | IRs | Single pass AHU | HEPA | UV | Pressure monitorsb | BP review | Negative pressure in IRs? | Recommendations and notes |
---|---|---|---|---|---|---|---|---|
A |
10 (S) |
Y |
N |
N |
N |
Y |
Y |
1c |
B |
6 (s) |
N |
N |
N |
N |
Y |
N |
2d |
C |
4 (S)
2 (s) |
Y |
Y |
N |
Y |
Y |
Y |
3e |
D |
3 (S)
9 (s) |
Y |
Y |
N |
Y |
Y |
Y |
|
E |
29 (s) |
Y |
N |
N |
Y |
Y |
N |
4f |
F |
2 (S)
72 (s)g |
N |
N |
N |
N |
Y |
N |
|
G |
20 |
Y |
N |
N |
Y |
Y |
Y |
5h |
H |
20 |
Y |
N |
N |
Y |
Y |
Y |
6i |
I |
2 (S)
20 (s) |
Y |
N |
N |
Y |
7j |
||
J | 8 (S) 19± (S) | Y | N | N | Y | Y | Y | 8k |
aIR, isolation rooms; AHU, air handling units; UVGI, ultraviolet germicidal irradiation; BP, blueprint or engineering designs plans available for review; S, standard isolation room; s, simple isolation room; Y, yes; N, no.
bPressure monitors were either digital or analog manometers installed outside patient room.
cRepair collapsed rooftop exhaust stack.
dInspect isolation rooms for leakage; four rooms not negatively pressurized.
eEnsure outdoor air intakes are not in proximity to exhaust fans for simple isolation rooms.
f32% isolation rooms were not negatively pressurized, no ICU, not recommended for SARS patients.
gProposed for construction as of 5/2003.
hVentilation system needs balancing/modification (negative pressure varied from –1.4 to –22 pascal). Extend rooftop exhaust stacks, establish standard operating procedures for personal protective equipment use, require handwashing for all hospital contractors.
iModify 2-way switches in simple isolation rooms so that fans cannot operate in reverse, replace wooden doorknobs with metal on SARS patient ward.
jModify 2-way switches in simple isolation rooms so that fans cannot operate in reverse, position patient beds with head of bed near source of room exhaust for increased isolation, seal wall, window, and ceiling penetrations in simple isolation rooms.
kModify 2-way switches in simple isolation rooms so that fans cannot operate in reverse, seal windows in simple isolation rooms to enhance negative pressure.