Skip directly to site content Skip directly to page options Skip directly to A-Z link Skip directly to A-Z link Skip directly to A-Z link
Volume 16, Number 11—November 2010
Research

Comparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening

An V. Nguyen, Nicole J. CohenComments to Author , Harvey Lipman1, Clive M. Brown, Noelle-Angelique Molinari, William L. Jackson, Hannah L. Kirking, Paige Szymanowski, Todd W. Wilson, Bisan A. Salhi, Rebecca R. Roberts, David W. Stryker, and Daniel B. Fishbein
Author affiliations: Centers for Disease Control and Prevention, Atlanta, Georgia, USA (A.V. Nguyen, N.J. Cohen, H. Lipman, C.M. Brown, N.A. Molinari, W.L. Jackson, H. Kirking, P. Szymanowski, T.W. Wilson, D.B. Fishbein); Council of State and Territorial Epidemiologists, Atlanta (A.V. Nguyen); Emory University, Atlanta (P. Szymanowski, B.A. Salhi); John H. Stroger, Jr. Hospital of Cook County, Chicago, Illinois, USA (R.R. Roberts); Presbyterian Healthcare Services, Albuquerque, New Mexico, USA (D.W. Stryker); 1Deceased.

Main Article

Table 3

Association between measured temperature, difference, and covariates, general linear regression with site-specific fixed effects in 3 emergency departments, USA, 2008–2009

Characteristics Oral,
n = 1,865 patients OptoTherm,
n = 1,851 patients Difference 
(oral–OptoTherm) FLIR, 
n = 1,360 patients Difference (oral–FLIR) Wahl, 
n = 1,856 patients Difference (oral–Wahl)
Intercept (SE) 98.220 (0.936) 15.027
(3.467) 14.426
(1.337) 15.777
(4.150) 14.309
(1.559) 13.160
(6.541) 21.769
(2.489)
Variable in model*
Oral temperature 0.701† 0.693† 0.645†
Male sex
–0.055‡
0.254†
–0.271†
0.237†
–0.260†
0.501†
–0.522†
Age 0.011‡ –0.160§ 0.019§ –0.029§ 0.034§ –0.001‡ 0.005‡
Age squared
–0.0002§
0.0001‡
–0.0002‡
0.0003§
–0.0004§
–0.002‡
0.0001‡
Site¶
Albuquerque –0.498† 0.915† –1.061† –0.214§ 0.058‡ 4.256† –4.431†
Atlanta
–0.309†
0.514†
–0.603†
0.302§
–0.399†
0.043‡
–0.149‡
Time of day 0.104§ 0.156§ –0.126§ 0.131§ –0.100‡ 0.352† –0.315†
Time of day squared
–0.003§
–0.004§
0.003‡
–0.003‡
0.002‡
–0.008§
0.007§
Antipyretic use 0.106§ 0.137§ –0.106§ 0.118* –0.086‡ 0.075‡ –0.039‡
Room temperature –0.010‡ 0.133† –0.137† 0.160† –0.162† 0.131† –0.135†
Self-reported fever (No) 0.432† 0.148§ 0.022‡ 0.149‡ 0.003‡ –0.115‡ 0.264§

*FLIR ThermoVision A20M (FLIR Systems Inc., Boston, MA, USA), OptoTherm Thermoscreen (OptoTherm Thermal Imaging Systems and Infrared Cameras Inc., Sewickley, PA, USA), and Wahl Fever Alert Imager HSI2000S (Wahl Instruments Inc., Asheville, NC, USA). Value of β coefficient (β) for each variable in the model is listed in the columns.
†p<0.001.
‡Not significant (p>0.05).
§p<0.05.
¶Referent site is Chicago.

Main Article

Page created: March 08, 2011
Page updated: March 08, 2011
Page reviewed: March 08, 2011
The conclusions, findings, and opinions expressed by authors contributing to this journal do not necessarily reflect the official position of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions. Use of trade names is for identification only and does not imply endorsement by any of the groups named above.